Skip to main content

WHY CHOOSE FOAM BOARD INSULATION?

Owens Corning FOAMULAR NGX 400, 600 and 1000 are high strength Extruded Polystyrene (XPS) Insulation products designed for use in engineered applications requiring additional load-bearing capability such as under slab, concrete floors, foundations.


Warning: This video contains flashing images that could trigger seizures for people with photo sensitivity.

FOAMULAR® NGX® High-Performance XPS Insulation

Owens Corning® FOAMULAR® NGX® insulation offers all the performance and ease-of-use you expect from Owens Corning® FOAMULAR® insulation with industry-leading sustainability. Learn how FOAMULAR® NGX® meets the new environmental regulations for Canada and a growing list of US states.

Resources

Product Focus: Owens Corning® FOAMULAR® NGX™ Insulation
Product Focus: Owens Corning® FOAMULAR® NGX™ Insulation

Technical Information


PROPERTY

TEST METHOD

COMPLIANCE:

Type 4

CAN/ULC-S701.1-17






PHYSICAL PROPERTIES:

Compressive Strength1 F-400: 40 psi (275 kPa)ASTM D1621
Compressive Strength1 F-600: 60 psi (415 kPa)ASTM D1621
Compressive Strength1 F-1000: 100 psi (690 kPa)ASTM D1621
Compressive Modulus F-400: 2000 psi (13789 kPa)ASTM D1621
Compressive Modulus F-600: 2700 psi (18616 kPa)

ASTM D1621

Compressive Modulus F-1000: 3700 psi (25510 kPa)ASTM D1621

Flexural Strength

ASTM C203

Flexural Strength2 F-600: 140 psi (965 kPa)ASTM C203
Flexural Strength2 F-1000: 150 psi (1034 kPa)ASTM C203
Dimensional Stability, Maximum, % linear change: 1.5ASTM D2126

Linear Coefficient of Thermal Expansion:
3.5x10-5 in/in./°F (6.3x10-5 mm/mm/°C)


ASTM E228

THERMAL

Thermal Resistance, R-Value, hr•ft2•°F/Btu (RSI, °C•m2/W)
5.0 (0.88) @ 24°C (75°F) mean temperature
5.4 (0.95) @ 4.4°C (40°F) mean temperature
5.6 (0.99) @ -3.9°C (25°F) mean temperature



ASTM C518 or C177

LTTR:See data sheet for valuesCAN/ULC-S770-15
MOISTURE:Water Absorption, (max. % by volume): 0.30ASTM D2842


Water Vapour Permeance (typical) FOAMULAR NGX: > 0.3 Perms (17 ng/Pa.s.m2)

ASTM E96


Water Capillarity: None



Water Affinty: Hydrophobic



Limiting Oxygen Index, min.: 24

ASTM D2863


FIRE:

Combustible

CAN/ULC-S114

Max. Service Temp. 74°C (165 °F)

1  Value at yield or 5%, whichever occurs first.

2  Values at yield or 10% deflection, whichever occurs first.

3  The R-value for FOAMULAR® NGX™ XPS Insulation is provided from testing at mean temperatures of: -3.9 °C (25 °F),

4  4 °C (40 °F), and 24 °C (75 °F) and aging techniques of 180-day real time aged (as mandated by ASTM C578).

Applications

  • Basements
  • Floors
  • Foundations
  • Foundations > Slab
  • Roofs
  • Roofs > Flat
  • Roofs > Pitched / Curved

Contact Us

Even though we’re a global company, we’re always ready to answer your questions. Call to speak with an Owens Corning representative.